Browse all practice questions for the Commercial Food Equipment Service Association (CFESA) Gas Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Commercial Food Equipment Service Association (CFESA) Gas Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What type of air do infrared burners require for optimal operation?
  • What must all outside combustion air openings be protected with?
  • What is the recommended installation guideline regarding the vent pipe connectors?
  • What causes flames with yellow tips?
  • How should one properly troubleshoot a combination gas valve?
  • How do you properly test the no-load output of a thermocouple?
  • What are aldehydes?
  • What is the appropriate length for a thermocouple lead?
  • What is the first step in lighting a pilot operated by a safety valve?
  • When the main burner ignites, what can cause the pilot to go out?
  • When is a flexible gas connector allowed for an equipment installation?
  • Why is it important to note the pipe size of both sides of a combination gas valve?
  • What is one sign that indicates the safety valve may be faulty?
  • What is the function of a Bunsen burner?
  • How hot must the sensor get on a hydraulic safety valve for it to function correctly?
  • In what units is gas pressure typically measured?
  • What will result if a burner manifold is not exactly perpendicular to the burner?
  • How can a downdraft create problems for gas equipment?
  • What type of wire is required from the ignition module to the igniter?
  • In troubleshooting an oven with an electronic spark ignition system that sometimes does not heat, what is the first step?
  • What effect does a hot ambient environment have on a thermocouple?
  • If all checks are okay in a troubleshooting scenario, what should you do next?
  • Which component must be flattened while correcting a loose thermostat shaft on a FD series thermostat?
  • How can you identify the proper installation direction for a gas regulator?
  • Why is double wall vent pipe necessary in venting systems?
  • What detail on the equipment data plate is infrared burners particularly sensitive to?
  • Hot surface igniters are manufactured in which of the following voltages?
  • What is a common indicator of inadequate primary air supply?
  • Before reassembling a burner valve, what should be inspected?
  • What does static pressure measure in gas systems?
  • What is a clear indication of the need to check gas pressure?
  • During flame rectification, in which direction is the current greater?
  • In addition to removing combustion byproducts, what is another function of the flue?
  • What property of igniters is typically a concern when handling or cleaning them?
  • How much air is required to burn one cubic foot of natural gas?
  • What is the hottest part of a flame?
  • Which characteristic of flame is crucial for thermocouples?
  • Which of the following is a dangerous byproduct of incomplete combustion?
  • Does the bypass flame on an FD thermostat go out if the flame is properly adjusted?
  • What aspect allows silicon nitride igniters to outperform older models?
  • What is the original material used in hot surface igniters?
  • The DC voltage generated by a thermocouple or thermopile is directly related to what factor?
  • When troubleshooting a hydraulic safety valve, what should you confirm about the sensor tip if the pilot lights but the main burner does not ignite?
  • What controls the secondary air to a burner?
  • What type of valve operates using a gas thermostat instead of a rocker arm?
  • What does a throttling thermostat refer to?
  • How do you adjust the bypass flame on a FD series thermostat?
  • What does a clogged vent fitting in a pressure regulator typically cause?
  • What causes LP gas to accumulate in a space?
  • How does a water manometer function?
  • What should be checked to determine natural gas operating pressure?
  • What material is primarily used in most modern hot surface igniters?
  • How is a GS thermostat used in conjunction with equipment operating at 150000 Btu?
  • Is a bleed type combination gas valve known for being fast or slow operating?
  • Where does natural gas primarily come from?
  • What is the minimum sized combustion air opening for a confined space connected to an unconfined space?
  • What is a potential issue if the inlet and outlet pipes of a gas valve are mismatched in size?
  • Why is it important to ensure proper grounding for CSST?
  • What part is responsible if the main burner stays on when the pilot goes out?
  • How tightly should a regulator be attached to the pipe fittings?
  • Where should the flame sensor be positioned within the flame?
  • What voltage range indicates a healthy safety valve using a thermocouple?
  • What is a common maintenance task to ensure igniters work effectively?
  • What is running pressure?
  • How is a BJ thermostat mounted to the equipment?
  • What is necessary to create a low NOX burner?
  • What is the maximum allowable dropout voltage for an electric safety valve using a thermopile?
  • What must be designed and installed with a power vent hood?
  • What is a bypass flame?
  • What is the output voltage of a thermopile under no-load conditions?
  • If carbon monoxide is being produced, will there be aldehydes?
  • Why is a manual gas shut off required at the equipment?
  • When should the ignition module stop sparking?
  • What does the term "lockout" refer to in gas ignition systems?
  • What is typically the first step in troubleshooting a burner issue?
  • What causes flames to lift off of a burner and maintain their shape?
  • For LP gas operating at 40000 Btu and 11 in/wc, what is the required orifice size?
  • If the pilot light goes out when the burners attempt to ignite, what might be wrong with the pressure regulator?
  • If the main burner does not achieve a full flame when using a hydraulic safety valve, what should be your first action?
  • What condition can cause extinction pop in a burner?
  • How can you determine if a gas problem is related to pressure or volume?
  • What is the method for calibrating a GS thermostat?
  • What is the main function of a gas thermostat in a bleed-type combination gas valve?
  • What should the pilot flame look like if functioning correctly?
  • How can you determine if a gas valve is in the 'on' or 'off' position?
  • What color should the surface of an infrared burner typically be?
  • What are the two basic types of disconnects?
  • What is one reason incomplete combustion can result in harmful byproducts?
  • What type of gas is typically used for heating and cooking in homes?
  • What type of lubricant is recommended for use on tapered plug gas valves?
  • Do all combination gas valves regulate the pilot gas pressure?
  • What is one major downside of the original hot surface igniters?
  • What differs between a vent and a flue?
  • What characteristic of silicon oxide affects the functionality of hot surface igniters?
  • What is the primary function of a thermopile?
  • Why do steel burners corrode prematurely?
  • What characteristic of LP gas contributes to its higher volatility compared to natural gas?
  • What are the two primary reasons that BJ thermostats start to leak gas around the knob?
  • Under what conditions is a multiple try ignition system allowed before a permanent lockout occurs?
  • What is the typical range for the heating value of natural gas?
  • Why is it crucial to monitor gas pressure accurately?
  • What characteristic identifies a properly functioning combustion flame?
  • What is the normal operating pressure for LP gas equipment?
  • What is a common symptom of BJ thermostat failure?
  • What is the key difference between yellow jacketed and black jacketed CSST tubing?
  • Under what circumstances should a draft hood be utilized?
  • What determines how much carbon dioxide your blood absorbs?
  • In a confined space, where must combustion air openings be located?
  • What kind of vents do most commercial kitchens have?
  • If all connections are good and components are clean, what is often the cause of low flame sensor current?
  • When connecting a hot surface ignition module, what must be ensured regarding the incoming power supply connections?
  • Why are low NOX burners becoming increasingly popular?
  • Commercial flexible gas lines must have what approvals to be acceptable in most code areas?
  • What effect can high incoming gas pressure have on pilot burners?
  • What is the function of a pressure regulator vent?
  • What is a common cause of flashback in a burner?
  • What is the main purpose of a restraining cable in gas equipment installation?
  • What is an FDH or FDTH thermostat used for?
  • What is one characteristic of LP gas regarding its volatility?
  • What is the maximum allowable dropout voltage for an electric safety valve using a thermocouple?
  • What can happen if a regulator is over tightened?
  • When checking gas pressure, should the burners be in an on or off position?
  • What is the equivalent length of a three-quarter tee if the direction of flow changes?
  • What is the purpose of gas pressure regulation in appliances?
  • What type of equipment commonly uses GS thermostats?
  • How much of the thermocouple tip should be covered by the pilot flame?
  • Are ball valves generally repairable?
  • What is the main risk of having undersized gas lines?
  • On what type of applications do you find FDO thermostats?
  • What characteristic of double wall vent pipe helps prevent fire hazards?
  • What is the purpose of adjusting the pressure regulator head?
  • What might indicate incomplete combustion in a burner?
  • What should be done with the tapered plug if there are deep scratches found during inspection?
  • What is the most common cause of thermocouple failures?
  • What does the solenoid coil portion of a combination gas valve control?
  • What symptom might indicate a problem with the pressure regulator?
  • What type of pad should be used to clean an igniter or flame sensor to avoid damage?
  • Why is running pressure important?
  • What is the typical resistance range for a normal hot surface igniter?
  • Which of the following conditions is NOT good for burner operation?
  • Why are manufacturers increasingly using inshot burners?
  • How is primary air controlled?
  • Can infrared burners be repaired or rebuilt?
  • What is one way to check the cleanliness of the igniter and flame sensors?
  • What indicates that a burner needs a primary air adjustment?
  • What is required to convert a combination gas valve from natural gas to LP gas?
  • What happens if a thermopile is not adequately covered by the pilot flame?
  • What problems can arise from a dirty vent on a combination gas valve?
  • What is the procedure for adjusting a bypass flame on a BJ thermostat?
  • What is the result of a poorly adjusted bypass flame in a gas appliance?
  • What is a potential issue if the dropout voltage on the safety valve is high?
  • What happens if a thermocouple is kinking during installation?
  • What should you do if the pilot flame is poor quality during troubleshooting?
  • Which statement is true regarding the operation of a safety valve?
  • How many byproducts remain after burning one cubic foot of natural or LP gas?
  • What might happen if the regulator vent becomes blocked with dirt?
  • Why are one-time lockout modules particularly needed?
  • Which size orifice is required for a natural gas system with a demand of 40000 Btu at 4.0 in/wc?
  • What does a proper make up air system prevent?
  • In a direct ignition system, what does the igniter actually light?
  • Why is clean combustion air needed for infrared burners?
  • How much of a thermopile must be covered by the pilot flame for optimal performance?
  • Is it advisable to replace a failed part of a combination gas valve?
  • What component senses the flame to prove ignition?
  • When should a 24v hot surface igniter be replaced?
  • Which type of manometer is considered the most accurate?
  • What should be the position of the manual shut-off valve relative to the equipment?
  • How should a thermocouple be stored before installation?
  • What is secondary air?
  • Which gas valve type is known for less likelihood of seizing up over time?
  • What is primarily responsible for a shapeless flame flowing totally off the burner?
  • How can proper air shutter adjustment affect burner performance?
  • What might indicate a gas regulator is defective?
  • What is the proper flame current range for a Honeywell spark ignition module?
  • How does LP gas compare to air in terms of weight?
  • Why is LP gas considered more dangerous to work with than natural gas?
  • What is the approximate heating value of a cubic foot of natural gas?
  • What does a gas pressure reading of 4 inches wc indicate on a U-Tube manometer?
  • When can you expect an FD thermostat's bypass flame to extinguish?
  • What will happen if a bypass flame is set too high?
  • Why is it critical to check the data plate for natural gas equipment?
  • If there are aldehydes, is there carbon monoxide present?
  • What is the purpose of measuring static pressure?
  • Which component on a gas valve can be adversely affected by improper lubrication?
  • What protective feature is incorporated into the construction of approved disconnects?
  • Why are dual gas valves necessary with spark ignition systems?
  • What effect does increasing the spring tension on a pressure regulator diaphragm have?
  • What happens as you increase the flame size on a non-aerated pilot burner?
  • How does the pressure regulator section of a combination gas valve function?
  • Is natural gas heavier or lighter than air?
  • What should be the first consideration when selecting a pressure regulator?
  • What is typically the first valve section on a redundant gas valve?
  • Can a vent pipe be directly connected to the flue on gas equipment?
  • What is an advantage of the new material used for hot surface igniters?
  • What are the three essential components required for combustion?
  • Combustion air openings should be situated at what measurements from both the floor and the ceiling?
  • What should be regularly maintained to ensure accuracy in gas pressure measurement?
  • How will the burner flame appear if the orifice is not properly aligned?
  • How does the mercury flame switch operate to close contacts?
  • Robertshaw FD thermostats are usually found in what type of equipment?
  • When should you consider replacing a BJ or FD thermostat?
  • What is the first step in troubleshooting a pilot burner that will not light on a system with a pilot safety valve?
  • What is the function of air shutters in a burner system?
  • How can you reset an ignition module that is in a locked out state?
  • What is a common source of LP gas?
  • What is the function of a burner orifice in gas equipment?
  • What type of pipe is typically required for natural gas lines?
  • What is a full port ball valve designed to do?
  • What does the gas code specify regarding the vent of an installed regulator?
  • What is critical when drilling an orifice?
  • Complete combustion of fuel primarily produces which of the following?
  • What type of flame is necessary for a thermocouple to function correctly?
  • What is meant by the term "port loading" in relation to burners?
  • What defines a redundant gas valve?
  • What is a significant advantage of using infrared burners?
  • What is the primary function of a manometer?
  • How does an electronic safety valve function?
  • What is the major cause of BJ thermostat failure?
  • How many different voltages are required for a hot surface ignition module using a 120V hot surface igniter?
  • Why is the size of the flue considered critical in gas equipment?
  • What is a potential consequence of having an off-center drilled orifice?
  • What is a significant downside of using a hot surface igniter as a flame sensor?
  • In what state is LP gas typically stored due to its properties?
  • Where must the manual gas shut off be installed?
  • A confined space connected to an unconfined space requires how much combustion air opening per 1000 Btus?
  • Why is it important to check the adjustment of the bypass flame?
  • Which of the following is a potential issue if incoming gas pressure is too low?
  • If a hot surface ignition module is inoperable, what other part should you also consider changing?
  • Where does the flame burn on a ceramic tile infrared burner?
  • What is the typical no-load output voltage range of a thermocouple?
  • What is the heating value for LP gas?
  • What material can be used for LP gas lines?
  • What is the normal flame current when using a hot surface ignition system?
  • What is the first step to correct a loose thermostat shaft problem on a FD series thermostat?
  • What is the minimum incoming gas pressure required for natural gas to prevent problems?
  • What is the minimum area required for a fresh air opening in a gas appliance?
  • What is a key step in calibrating a FD thermostat?
  • What is the primary composition of natural gas?
  • Which safety measure is crucial when handling LP gas?
  • What does a blue flame indicate on an infrared burner?
  • What type of components are replaced if the igniter is consistently operating at high amperage?
  • What should you do after adjusting the shaft plate on a FD thermostat?
  • What typically causes the seals between the tiles of infrared burners to decay?
  • What is the function of a hot surface igniter in a gas ignition system?
  • What precaution should be taken when installing a new thermocouple?
  • What action should be taken if the pilot lights but the main burner does not come on in a system with an electric safety valve?
  • What is the primary cause of most infrared burner failures?
  • Which gas is more volatile due to its higher Btu rating and density?
  • What are the byproducts of complete combustion?
  • What factors determine the gas flow rate through an orifice?
  • What is a downdraft in the context of gas venting?
  • What electrical codes must be followed when using CSST tubing?
  • Can the tapered plugs in tapered plug gas valves be interchanged?
  • What is the correct flame current value for a Johnson Controls G700 series ignition module?
  • What indicates that a burner has a secondary air problem?
  • What might be a common cause of misdiagnosing mercury flame switch failures?
  • What overall effect do cracks in the hot surface igniter material have?
  • What does the hot junction of a thermocouple refer to?
  • What is the purpose of the stainless steel braid on a commercial flexible gas connector?
  • If a pilot goes out when the main burner comes on, where is the problem most likely found?
  • What are the two key functions of primary air in an infrared burner?
  • What method is commonly used to check for gas leaks?
  • How tight should the nut on the end of the thermocouple be when secured?
  • How does a thermocouple generate an electrical current?
  • What mechanism does a hydraulic safety valve use to operate?
  • For a combustion air opening directly to the outside or through a vertical duct, how much space is required per 4000 Btus?
  • When is lockout supposed to occur in an ignition system?
  • What is a combination gas valve used for?
  • What are the three major functions of the spark ignition module?
  • How does the ignition module differentiate between a flame and a sensor shorted to ground?
  • Where is the bypass adjustment located on a BJ thermostat?
  • What important factor needs to be considered for vent pipe sizing?
  • Which type of orifice is larger for 1000 Btu: natural gas or LP gas?
  • In what scenarios might local jurisdictions allow exceptions to using black iron pipe?
  • Why are many gas lines found to be undersized?
  • What type of burner typically operates at higher temperatures to reduce emissions?
  • What must be avoided when mounting the sensor of a hydraulic safety valve?
  • What can happen if an orifice is drilled off center?
  • What size orifice is needed for a natural gas appliance operating at 30000 Btu with a pressure of 3.5 in/wc?
  • What type of sealants should be used on natural gas fittings?
  • What is one of the main factors in determining the size of gas piping according to gas code?
  • Which term best describes the operational capability of a properly functioning BJ or FD thermostat?
  • What causes an almost totally yellow flame in a gas appliance?
  • Why is it crucial to understand the flame current for hot surface igniters?
  • Which of the following gases are classified as LP gas?
  • How do you check the flame sensor current when a separate flame sensor is used?
  • What occurs in an LP tank when gas is drawn off?
  • What is the consequence of having less temperature difference between the hot and cold junction?
  • What is one advantage of using ball valves over tapered plug valves?
  • If horizontal ducts are used to bring in fresh air, how much space is needed per 2000 Btus?
  • Which of the following statements is true regarding convection ovens?
  • What is the second gas valve section referred to on a dual gas valve?
  • Can pilot burners wear out, and how can you tell?
  • In what type of cooking equipment are bleed type combination gas valves commonly utilized?
  • Can hydraulic safety valves fail partially open?
  • On what type of applications do you find FDTO thermostats?
  • For two ovens, each rated at 80,000 Btus, what size vent pipes are required if the roof height is 10 feet?
  • What happens if the calibration of the bypass flame is off from the knob on a FD thermostat?
  • What is the primary function of a draft hood in gas equipment?
  • What happens when there is an insufficient flow of secondary air?
  • What is the best method for checking a hot surface igniter?
  • Which gas measurement tool is used for checking pressure differentials?
  • What components does a combination gas valve typically integrate?
  • What steps should be taken to repair a tight tapered plug gas valve?
  • How do dirty connections impact thermocouples?
  • What is primary air?
  • When checking microamps in a troubleshooting scenario, what should you check if the microamp reading is low?
  • Why is it necessary to hold down the button on the safety valve after the pilot burner lights?
  • If the burner lights but the igniter continues to spark, what part is likely faulty?
  • Which component directly influences the working gas pressure in a combination gas valve?
  • What size vent pipe is needed for equipment rated at 160,000 Btu located 10 ft from the roof opening?
  • Which procedure should be followed to adjust the primary air on a burner?
  • What typically causes whistling at the burner orifice?
  • Which of the following can indicate that the gas pressure is too low?
  • What can a malfunctioning flame sensor lead to?
  • What is the maximum amp draw for a 120v hot surface igniter?
  • What is essential to check for differing voltages in hot surface ignition systems?
  • What are potential ways a new thermocouple can be damaged during installation?
  • On which side of the flexible gas connector is the female section of the quick disconnect installed?
  • What should the normal millivolt reading be under load for a safety valve using a thermocouple?
  • What is a major concern when using a gas meter to measure gas flow?
  • What issue can occur when oven doors do not shut tightly?
  • What is the function of a spoiler screw in a burner?
  • What is the major difference between a commercial and domestic flexible gas connector?
  • How is LP gas stored in tanks?
  • What is a common maintenance task for pressure regulators?
  • What must be done to orifices when converting from natural gas to LP gas?
  • What condition should be avoided to prevent explosions in gas systems?
  • What maintenance task is critical for ensuring the reliability of hot surface igniters?
  • Describe the proper flame for an aerated pilot burner.
  • How does higher altitude affect the function of an orifice?
  • What information is necessary to obtain a replacement combination gas valve?
  • When inspecting a tapered plug valve, what should you look for on the plug surface?
  • What can be done to minimize extinction pop?
  • What is the method for checking flame sensor current when the igniter also serves as the sensor?
  • What is the ideal flame color for optimal burner performance?
  • What component is likely at fault if pilot gas continues to flow after the pilot has been out for a few minutes?
  • What controls the primary air to a burner?
  • What is one purpose of the ground bonding codes for CSST?
  • Is the regulator vent located on the inlet side or outlet side of the regulator?
  • What condition can cause a downdraft to occur?
  • When mounting a BJ thermostat to a flange, what must you be careful of?
  • A three-quarter elbow is equivalent to how long a pipe?
  • What can happen if the hot surface igniter is shorted?
  • What is a common problem experienced when using a domestic connector in a commercial installation?
  • What type of vent pipe is recommended for commercial applications?
  • What common issue can cause intermittent operation of hot surface ignition systems?
  • Why is carbon monoxide considered particularly dangerous?
  • Why is maintaining proper air ratios crucial in a combustion system?
  • What does "specific gravity" refer to in terms of gas?
  • For a complaint that the pilot will not stay lit, which step should you take first on an electric safety valve?
  • Why is gas pressure crucial for impingement target burners?
  • Which factor does NOT typically affect the life expectancy of a hot surface igniter?
  • Why are infrared burners favored for use in broilers?
  • How is outside combustion air typically opened for ventilation?
  • What can happen if a downdraft disrupts the combustion chamber?
  • To convert orifices from LP to natural gas, what is the recommended action?
  • What does the diaphragm in a combination gas valve do?
  • When operating, what color do Low NOX burners typically show?
  • What does the gas code specify regarding gas piping size?
  • Before checking the calibration on any gas thermostat, what should you check?
  • What is the exact procedure for recalibrating a BJ thermostat?
  • What are the primary functions of a bypass flame?
  • How should the sensor on a hydraulic safety valve be mounted in the pilot burner?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy